Operation
X5
, X7
, ProX7
& ProX9
Airless Sprayers
312001R
EN
- For portable spray applications of architectural paints and coatings -
X5 & X7 Models ONLY: Use water-based or min-
eral spirit-type materials only. Do not use materi-
als having flash points lower than 70° F (21° C).
This includes, but is not limited to, acetone,
xylene, toluene, or naptha. For more information
about your material, request MSDS from distribu-
tor or retailer.
Models 262800, 262805, 261815, 261820
See page 2 for model and series information including
dispense rate, recommended hose length, guns, and
maximum working pressure.
IMPORTANT SAFETY INSTRUCTIONS.
Read all warnings and instructions in this
manual. Save these instructions.
MAGNUM X5
Model: 262800
ti11304a
Series D
MAGNUM X7
Model: 262805
ti11305a
Series C
M
AGNUM ProX7
Model: 261815
ti9369b
Series B
MAGNUM ProX9
Model: 261820
Series B
ti16976a
The manual provided with
this sprayer contains
English and Español.
Visit our website;
http://M
AGNUM.Graco.com
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - Operation

OperationX5™, X7™, ProX7™ & ProX9™ Airless Sprayers312001REN- For portable spray applications of architectural paints and coatings - X5 & X7 M

Página 2 - Specifications

Operation 10 312001ROperationTrigger LockAlways engage the trigger lock when you stop spraying to prevent the gun from being triggered accidentally by

Página 3 - WARNINGWARNINGWARNING

Setup312001R 11Setup1. Unscrew tip and guard assembly from gun.2. Uncoil hose and connect one end to gun. Use two wrenches to tighten securely3. Conne

Página 4

Setup 12 312001R1. Make sure the power switch is OFF and the sprayer is unplugged.2. Separate prime tube (smaller) from suction tube (larger).3. Place

Página 5

Setup312001R 13Install Tip and Guard on Gun1. Engage trigger lock.2. Verify tip and guard parts are assembled in order shown.3. Screw tip and guard as

Página 6

Setup 14 312001RGetting StartedUse a piece of scrap cardboard to practice these basic spraying techniques before you begin spray-ing the surface.• Hol

Página 7 - Thermal Overload

Setup312001R 15Tip SelectionSelecting Tip Hole SizeTips come in a variety of hole sizes for spraying a range of fluids. Your sprayer includes an 0.015

Página 8 - Component Identification

Setup 16 312001RUnderstanding Tip NumberThe last three digits of tip number (i.e.: 221413) contain information about hole size and fan width on surfac

Página 9

Shutdown and Cleaning312001R 17Shutdown and CleaningPail Flushing• For short term shutdown periods (overnight to two days) refer to Short Term Storage

Página 10

Shutdown and Cleaning 18 312001RNOTE: Step 12 is for returning paint in hose back to paint pail. One 50-ft hose holds approximately 1-quart (1-liter)

Página 11 - Prime and Flush Storage Fluid

Shutdown and Cleaning312001R 19Power FlushPower flushing is a faster method of flushing. It can only be used after spraying water-based coatings.1. Re

Página 12 - 11. Transfer suction tube to

Specifications 2 312001RSpecificationsThis equipment is not intended for use with flammable or combustible materials used in places such as cabinet sh

Página 13 - Spraying Techniques

Shutdown and Cleaning 20 312001RNOTE: Step 16 is for returning paint in hose back to paint pail. One 50-ft (15-m) hose holds approxi-mately 1-quart (1

Página 14 - Getting Started

Shutdown and Cleaning312001R 21Cleaning InstaClean™ Fluid Filter (ProX Sprayers Only)The InstaClean Fluid Filter prevents particles from entering pain

Página 15 - Choosing the Correct Tip

Storage 22 312001RStorageShort Term Storage (up to 2 days)1. Relieve pressure, page 10. 2. Leave suction tube and prime tube in paint pail.3. Cover pa

Página 16 - 16 312001R

Storage312001R 23Stowing Sprayer1. Screw inlet screen onto suction tube.2. Coil hose. Leave it connected to sprayer. Wrap hose around hose wrap bracke

Página 17 - Shutdown and Cleaning

Maintenance and Service 24 312001RMaintenance and ServiceCaring for SprayerKeep sprayer and all accesso-ries clean and in good working order.To avoid

Página 18 - 18 312001R

Troubleshooting312001R 25TroubleshootingCheck everything in this Troubleshooting Table before you bring the sprayer to a Graco/MAGNUM authorized servi

Página 19 - Power Flush

Troubleshooting 26 312001RPump does not prime. Prime/Spray Valve is in SPRAY position.Turn Prime/Spray Valve to PRIME position (pointing down).Inlet s

Página 20 - 20 312001R

Troubleshooting312001R 27Pump cycles but does not build up pressure.Pump is not primed. Prime pump.Inlet screen is clogged . Clean debris off inlet sc

Página 21 - Cleaning Gun

Troubleshooting 28 312001RPressure is set at maximum but cannot achieve a good spray pattern.Reversible spray tip is in UNCLOG position.Rotate arrow-s

Página 22 - Long Term Storage

Troubleshooting312001R 29Fan pattern varies dramatically while spraying.ORSprayer does not turn on promptly when resuming spraying.Pressure control sw

Página 23 - Stowing Sprayer

Warnings312001R 3WarningsThe following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point sym

Página 24 - Maintenance and Service

Technical Data 30 312001RTechnical DataMAGNUM X5 (Series D) MAGNUM X7 (Series C)Working pressure range 0-3000 psi (0-21 MPa, 0-207 bar) 0-3000 psi (0-

Página 25 - Troubleshooting

Technical Data312001R 31MAGNUM ProX7(Series B)MAGNUM ProX9(Series B)Working pressure range 0-3000 psi (0-21 MPa, 0-207 bar)Electric motor 5.8A (open f

Página 26 - Problem Cause Solution

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Página 27

Warnings 4 312001RFIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire

Página 28

Warnings312001R 5SKIN INJECTION HAZARD • Do not aim the gun at, or spray any person or animal.• Keep hands and other body parts away from the discharg

Página 29

Warnings 6 312001RELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.•

Página 30 - Technical Data

Grounding and Electric Requirements312001R 7Grounding and Electric RequirementsSprayer must be grounded. Grounding reduces the risk of static and elec

Página 31 - MAGNUM ProX9

Component Identification 8 312001RComponent IdentificationA Airless spray gun Dispenses fluid.B Power switch Turns sprayer ON and OFF.C Pressure contr

Página 32 - Graco Standard Warranty

Component Identification312001R 9JEDXBKWFCGLHQRASTti9669ati9667aMti9368bC1ti9346ati9670aF1Uti9724ati16978aV (SG2/SG3)

Comentários a estes Manuais