Parts manuals available online! www.m-p-llc.com
POWER PRODUCTS LLC
DIESEL GENERATOR
75
MMG75D • MMG100D
OPERATING MANUAL
Vista de página 0
1 2 3 4 5 6 ... 55 56

Resumo do Conteúdo

Página 1 - OPERATING MANUAL

Parts manuals available online! www.m-p-llc.comPOWER PRODUCTS LLCDIESEL GENERATOR75MMG75D • MMG100DOPERATING MANUAL

Página 2 - MAGNUM POWER PRODUCTS LLC

10SAFETY SYMBOL SUMMARYThis equipment has been supplied with numerous safety and operating decals. These decals provide important operating instructio

Página 3 - TABLE OF CONTENTS

11SPECIFICATIONS - MMG75DRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or dea

Página 4

12SPECIFICATIONS - MMG100DRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or de

Página 5

13UNIT DIMENSIONSRead this manual carefully before attempting to use this generator. The potential for property damage, personal injury or death exist

Página 6 - OPERATING SAFETY

14UNIT SERIAL NUMBER LOCATIONSRefer to the locations illustrated below to find the unit ID tag and VIN tag on your unit. Important information, such a

Página 7 - ELECTRICAL SAFETY

15COMPONENT LOCATIONSVoltageSelectorSwitch AccessHandleFront HoodLatchEngineExhaustFuel FillOil DrainPortRadiatorDrain PortControlPanel AccessEmergenc

Página 8 - TOWING SAFETY

16MAIN CONTROL PANEL FEATURES, STANDARD256791011184312AUTO EXHAUSTFILTER CLEANINGLIMPIEZA AUTOMÁTICADE FILTRO DE ESCAPEAUTOMATISCHEABGASFILTERREINIGUN

Página 9

171. MAIN CIRCUIT BREAKER: This breaker will disconnect power to the connection lugs (items 10-11). It WILL NOT disconnect power to the convenience ou

Página 10 - SAFETY SYMBOL SUMMARY

18MAGNUM DIGITAL CONTROLLER (MDC)The Magnum Digital Controller (MDC) is an enhanced digital generator controller used to start, stop and monitor the o

Página 11 - SPECIFICATIONS - MMG75D

19• “AUTO ” Button: Press this button to change from Manual starting mode to Automatic (remote) starting mode.• “ALARM CANCEL” Button: When an alarm

Página 12 - SPECIFICATIONS - MMG100D

2INTRODUCTIONThis manual provides information and procedures to safely operate and maintain the engine and generator. For your own safety and protecti

Página 13 - UNIT DIMENSIONS

20• Oil Pressure: Displays engine oil pressure. The display registers oil pressure between 0-100 psi (0-689 kPa). Normal operating pressure is between

Página 14 - UNIT SERIAL NUMBER LOCATIONS

21• “Password” screen: The operator may press the “” or “” buttons on the “DIAGNOSTICS” keypad to move the cursor (>) up or down a list of text.•

Página 15 - COMPONENT LOCATIONS

22• “DPF Inhib” area: This area will display the “Disabled Regeneration” indicator above the words “DPF Inhib” when auto exhaust filter cleaning is di

Página 16 - FILTER CLEANING

23To adjust the output voltage, check the output voltage on the generator display screen. Look at the “L1N” voltage or the “L12” voltage on the displa

Página 17

24 TO CLOSE THE FRONT HOOD:1. Make sure the skid is free of debris and all personnel are clear of unit. CAUTIONDo not attempt to close the hood from t

Página 18

25MANUAL STARTING OF THE GENERATOR1. Move the control ON/OFF toggle switch to the “CONTROL ON/I” position.DANGERCARBON MONOXIDE: USING A GENERATOR IND

Página 19 - ENGINE MONITORING

266. The Running screen will display. Note: It may take a few seconds for the engine to run smoothly and reach its governed operating speed. The 45 se

Página 20 - BINARY OUTPUTS SCREEN

27“AUTO” (REMOTE) STARTING OF THE GENERATORThe “AUTO” button is used when the generator is started from a location other than the control panel and by

Página 21

28EXHAUST FILTER CLEANING OPERATIONSWhen enabled, the exhaust filter system goes through an automatic cleaning process known as regeneration. Under no

Página 22 - FINE VOLTAGE ADJUSTMENT

29MDC CONTROLLER INFORMATION DISPLAYS, FUNCTIONS, AND RESETThe Magnum Digital Controller (MDC) constantly monitors vital generator and engine function

Página 23 - Figure A

3TABLE OF CONTENTSPageINTRODUCTION ...

Página 24 - PRE-START CHECK LIST

30MAGNUM DIGITAL CONTROLLER (MDC) - LIST OF ALARMSShutdown and warning fault conditions and the displayed message are described in the following table

Página 25

31JOHN DEERE ECU INFORMATION DISPLAYS AND FUNCTIONSThis unit has a John Deere Electronic Engine Control Unit (ECU) which regulates the engine speed (r

Página 26 - OFF MAN AUT

32*Note: The Suspect Parameter Number (SPN) is displayed as “FC” on the bottom left of the LCD window. Refer to Figure 1.MDC CONTROLLER – HISTORYThe M

Página 27 - SHUTTING DOWN THE GENERATOR

33ADJUSTING THE DISPLAY BACKLIGHTINGThe brightness on the Liquid Crystal Display (LCD) window may be adjusted by the operator whenever the Magnum Digi

Página 28

343. If the oil level is good, restart the unit and verify the loss of oil pressure. Shut the engine down immediately if the oil pressure value does n

Página 29

35GENERATOR OUTPUT CONNECTION LUGSThe generator is equipped with connection lugs behind the lug box door located on the lower portion of the control b

Página 30

36VOLTAGE SELECTOR SWITCHThe voltage selector switch is located on a panel attached to the generator behind the door located next to the fuel tank fil

Página 31 - Figure 1

374-POSITION VOLTAGE SELECTOR SWITCH OPTIONThe optional four position voltage selector switch is located on a panel attached to the generator behind t

Página 32 - MDC CONTROLLER – HISTORY

38EMERGENCY STOP SWITCHThe generator is equipped with one emergency stop switch, located on the right rear corner of the unit next to the control door

Página 33

39CUSTOMER CONVENIENCE OUTLETSThe generator is equipped with five convenience outlets. The large outlets are 240/120VAC twist-lock receptacles rated a

Página 34

4FUEL TRANSFER PUMP OPTION ... 45VISCOUS FAN CLUTCH OPTI

Página 35 - RUN CABLES THROUGH SLOTS

40TRANSFER SWITCHWhen the generator is used as a standby power supply, it must be equipped with a transfer switch which isolates it from the utility’s

Página 36 - VOLTAGE SELECTOR SWITCH

41BELT TENSIONJohn Deere engines use two types of belt tensioners: manual and automatic. Adjust the belt using the manual tensioner according to the m

Página 37

42• Never wash the engine block or fuel tank with a power washer or steam cleaner. Water may enter the cabinet and collect in the generator windings o

Página 38 - VOLTAGE REGULATION

43 * Replace primary air cleaner when dust valve restriction indicator gauge shows a vacuum of 25 in. H2O. ** Change the oil and oil filter after the

Página 39 - REMOTE START TERMINAL BLOCK

44LIFTING THE GENERATORA large central lifting eye is located on the top of the generator. The eye is connected to a central lifting frame inside the

Página 40 - TRANSFER SWITCH

45CHECKING GENERATOR DRIVE PLATE TORQUEFollow the procedure below to check the torque of the generator drive plate bolts in accordance with the mainte

Página 41 - AUTO EXERCISE TIMER

46VISCOUS FAN CLUTCH OPTIONThe viscous fan clutch option allows the engine cooling fan to engage at lower speeds, and disengage at higher speeds, incr

Página 42 - DAILY WALK AROUND INSPECTION

47AC WIRING DIAGRAM - 3 POSITION VOLTAGE SELECTOR SWITCHBREAKER240V 50ABRN 240V 50ABREAKER240V 50ABREAKERBLK BLK BLK BLK BRN 5913610 147811121516T5BLK

Página 43 - ENGINE BREAK-IN REQUIREMENTS

48AC WIRING DIAGRAM - 4 POSITION VOLTAGE SELECTOR SWITCH OPTIONBRNGRN/YEL 10GA(T7)CT-3L2L3SHUNTL1CT-2CT-1BREAKERGRN/YEL 14GAGRN/YEL 10GAGRN/YEL 10GA(2

Página 44 - Central Lift Eye

49AC WIRING DIAGRAMS FOR OPTIONAL EQUIPMENTCIRCUITBREAKERCAMLOCKPANELGNDL0L1 L3L265872VOLTAGE RELAYH1 H3X2X4 X1X3H2 H4BLK RED POWERRELAYBLKBLKWHTWHTWH

Página 45 - FUEL TRANSFER

This Page Intentionally Left Blank5

Página 46 - VISCOUS FAN CLUTCH OPTION

50DC WIRING DIAGRAMPLUG LOCATIONRPMPINRPM INRPM GNDMAG INMAG REFD+PLUG LOCATIONPOWER + DC+RELAY BOARDD+LOWERE STOPBI17 PIN PLUG (BINARY INPUTS)BO1C1 +

Página 47 - 90250_A_03.13.13

51DC WIRING DIAGRAMS FOR OPTIONAL EQUIPMENTJHDEUTSCH21 PIN CONN-2EDISON PLUG16/3BRNBLUYEL/GRNFANCLUTCHRELAYTOCONTBO7BOTTOMPINE STOPBI16 PIN PLUG (BINA

Página 48 - 90296_A_10.26.12

52WIRING BLOCK DIAGRAM - DEDICATED 12 LEAD GENERATORS OPTIONLOL3 L2 L1TO CONTROL BOXLOL3 L2 L1TO CONTROL BOXLOL3 L2 L1TO CONTROL BOXLOL3 L1TO CONTROL

Página 49 - 90415_E_03.19.13

53TRAILER WIRING DIAGRAMTRAILER PLUGTRAILER PLUGGNGNBKBKYLYLBNBNBNBNWTWTLAMPMARKERAMBERWTWTWTWTAMBERMARKERLAMPBKBKWTWTREDMARKERLAMPBKBKBKBKLAMPMARKERW

Página 50 - DC WIRING DIAGRAM

54WIRING HARNESS - ELECTRIC BRAKE OPTION90286_D_10.31.12BATTERYBREAKAWAYSWITCHBLUWHT BLKWHT WHTWHTWHTBRAKEBLUBLUBRAKEWHTBLU BLUBLUBLUWHTBRAKEBLUBLUBRA

Página 51 - INTERIOR

55SERVICE LOGOIL GRADE AND TYPE: ___________________________ BRAND: ___________________________________COOLANT MIXTURE: ____________________________

Página 52 - 90302_A_11.06.12

REV: BPART NO: 3266803.15.13

Página 53 - TRAILER WIRING DIAGRAM

6SAFETY NOTESThis is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this

Página 54 - 90286_D_10.31.12

7ENGINE SAFETYInternal combustion engines present special hazards during operation and fueling! Failure to follow the safety guidelines described bel

Página 55 - SERVICE LOG

8TOWING SAFETYTowing a trailer requires care! Both the trailer and vehicle must be in good condition and securely fastened to each other to reduce t

Página 56 - 03.15.13

9REPORTING TRAILER SAFETY DEFECTSIf you believe your trailer has a defect which could cause a crash or could cause injury or death, you should immedia

Comentários a estes Manuais

Sem comentários